2020 NEC Code Reference

Indexed GIES field reference for article lookup, bookmarks, and local notes. Full NEC text is not bundled.

Copyright-safe operating rule

This section is an index and note layer only. Use your licensed 2020 NFPA 70 / NEC book, NFPA LiNK access, or AHJ-published adopted code source for exact enforceable text. Do not treat this page as the full code.

81 indexed itemsLocal notes enabledFull text not stored

Code Quick Cards

Short GIES field cards are grouped directly in the code tab below. Use the full cards when you need the detailed bullet list, exceptions, and gotchas.

Open Full Quick Card LibraryLegacy Common Cards

Chapter 2 - Wiring and Protection

1
Motor Branch-Circuit Basics
Ref: 430.6; 430.22; 430.32; 430.52 · motor, FLC, overload, OCPD

Motor full-load current used for conductor and branch-circuit short-circuit/ground-fault protection calculations is generally determined from the Article 430 tables as...

Equipment / Special Equipment

1
Motor Disconnecting Means
Ref: 430.102; 430.109 · motor disconnect, within sight, controller

Disconnecting means shall be provided for the controller and motor as required by 430.102. Exception/watch: Lockable disconnect provisions can affect the within-sight...

Chapter 2 - Wiring and Protection

1
Article 240 - Overcurrent Protection
Chapter 2 - Wiring and Protection · OCPD

Breaker/fuse protection rules, standard ratings, tap conductors, conductor protection, and equipment protection.

Keywords: breaker, fuse, OCP, overcurrent, tap conductor, 240.4, 240.6

Related: 310, 408, 430

Chapter 4 - Equipment for General Use

3
Article 404 - Switches
Chapter 4 - Equipment for General Use · Devices

Switch installation, switching of grounded conductors, snap switches, and enclosure requirements.

Keywords: switch, snap switch, disconnect switch

Related: 406, 430

Article 430 - Motors, Motor Circuits, and Controllers
Chapter 4 - Equipment for General Use · Motors

Motor conductor sizing, overloads, short-circuit protection, disconnects, and controller rules.

Keywords: motor, overload, MCC, starter, disconnect, VFD

Related: 240, 440, 460

Article 440 - Air-Conditioning and Refrigerating Equipment
Chapter 4 - Equipment for General Use · HVAC

A/C and refrigeration disconnects, conductor/OCP sizing, MCA/MOCP labels, and HVAC equipment rules.

Keywords: HVAC, air conditioner, MCA, MOCP, condenser, disconnect

Related: 430, 422

Chapter 6 - Special Equipment

1
Article 620 - Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts
Chapter 6 - Special Equipment · Elevators

Elevator/lift electrical equipment, disconnects, and coordination references.

Keywords: elevator, lift, escalator, disconnect

Related: 430, 645